Ceph

At a glance

  • What the view shows: an overall skeletal overview in a familiar projected radiographic format, reproducible off the same scan.
  • Start: pick a projection preset (Lateral L, Lateral R, PA, or AP), click Auto contrast, then choose the average projection or MIP.
  • Three gestures: drag on the image horizontally to turn the head and vertically to nod it; the Turn and Nod sliders do the same numerically; double-click a slider to zero it. The Keys card lists every gesture of the mode.
  • Leave it for: any ambiguity of superimposition (MPR is one mode switch away), and landmarks, tracing, or measurements, which this mode does not have.

Ceph on the consented real CBCT: a lateral virtual cephalogram as a densest-only MIP after auto contrast, with the projection presets, the Turn and Nod controls, and the shared window in the sidebar

What this mode is for

Ceph renders a virtual cephalogram: the whole volume projected flat along one viewing direction, like a film. Every structure along each ray is integrated into one 2D radiograph, so the result reads like a conventional cephalometric or skull projection reconstructed from the same scan. It answers the projection questions: an overall skeletal overview in a familiar radiographic format, and a reproducible 2D image that can be regenerated at exactly the same geometry from the same volume.

Gestures

Gesture Where Action
Horizontal drag the image Turn the head about the vertical axis
Vertical drag the image Nod the head (sagittal tilt)
Double-click a slider controls Zero it

While dragging, the projection renders at a coarse stride and refines to full resolution when you let go. The current turn and nod are shown on the image.

The controls

Control Options or range What it does
Pane the cephalogram The projection's name sits top left, followed by its turn and nod once either is off zero; the window reads bottom right.
Projection presets Lateral L, Lateral R, PA, AP Lateral L is the profile looking from the left, Lateral R the profile looking from the right, PA the front (postero-anterior), AP the front (antero-posterior). Picking a preset zeroes the rotation sliders; the selected preset is solid blue.
MIP (densest only) checkbox Unchecked, the projection is the average along each ray, the film-like look with every structure summed; checked, only the densest structure per ray survives, a bone-forward look.
Turn -180 to 180 degrees Rotation about the vertical axis.
Nod -60 to 60 degrees Sagittal tilt.
Contrast the shared Window section The cephalogram is windowed by the sidebar's shared Window section, one set of center, width, and gamma controls for the whole app, so the numbers you read there are the numbers this image uses. The shared invert checkbox produces the film-negative rendering.
Auto contrast toggle Computes a window from the projection's own densities (the projected values are not slice HU, so the volume window is usually not the right one) and writes it into that shared section; the button stays solid blue only while that window is still active.
Reset window button Returns to the automatic volume window.
Snapshot header button Saves the current cephalogram with a caption carrying the volume id, the projection name, and the date.

A reading workflow

  1. Pick the preset that matches the question: a lateral projection for the profile view, PA or AP for the frontal view.
  2. Run Auto contrast first; the integrated projection has its own density range and the slice window rarely suits it.
  3. Choose the blend for the purpose: the average projection for the familiar radiographic appearance with soft-tissue outline, MIP when only the densest structures should survive superimposition.
  4. Use small turn and nod corrections to compensate for head positioning in the scanner, so bilateral structures superimpose the way a positioned film would show them.
  5. Read the projection as you would the corresponding radiograph, keeping in mind that everything along each ray is superimposed.
  6. Resolve any ambiguity of superimposition in MPR: the same volume is one mode switch away, and that is the advantage over a film.
  7. Adjust gamma when the midtones need lifting or compressing after the window is set.
  8. Save the PNG when the projection itself is the record; the same geometry can be reproduced later from the turn and nod readouts.

Over MCP

open_scan, list_volumes, select_volume, set_view_mode (mode ceph), set_window_level, and snapshot apply. set_window_level adjusts the shared window the cephalogram is rendered with; Auto contrast is an on-screen control that writes into the same shared window. navigate_slice has nothing to move here (it works in MPR, grid, and pano) and answers with a clear error. Example sequence: set_view_mode to ceph, set_window_level with invert: true for a film-negative look, snapshot.

Limits

This is a parallel projection of the volume, not a true cephalostat exposure: there is no focal-spot geometry and none of the projective magnification a film device produces, so it is measurable and reproducible off the same scan but not interchangeable with a device-acquired cephalogram. There are no landmark or tracing tools in this mode, and no measurement tools; it produces an image, nothing more. CBCTScope is navigation and visualization only: no findings, no diagnoses. Research use only; not a medical device.